Simco-Ion FMX-002 Go to product viewer dialog for this item.
is a legacy handheld electrostatic fieldmeter used to locate and measure static charges. While largely replaced by newer models like the FMX-003 and FMX-004, its core operation remains consistent with these current versions. Core Specifications Measurement Range: Typically measures up to ±20plus or minus 20 kV (20,000V) at a distance of 1 inch. Accuracy: Approximately of the reading.
Distance Indication: Uses two LED guide lights; when these two points converge into a concentric circle on the target surface, the meter is at the correct 1-inch (25mm) measuring distance. Power: Operates on a standard 9V battery. Quick Operating Guide Simco FMX-002 Electrostatic Fieldmeter Calibration
Simco-Ion FMX-002 Go to product viewer dialog for this item.
(often succeeded by the FMX-003 and FMX-004) is a handheld electrostatic fieldmeter used to measure static charges in industrial environments. It uses an oscillating voltage sensor to detect the strength and polarity of surface charges. 📋 Technical Specifications Measurement Range: Up to (20,000V). Measuring Distance: Exactly 1 inch ( ), guided by two integrated LED ring lights. Power Source: 9V Manganese battery (typically 6F22).
Indicator: Analog/Digital LCD display with battery capacity and bar graph. ⚙️ Operating Instructions Follow these steps for accurate static measurement:
Grounding: Ensure the unit is grounded by connecting the provided ground wire to a known Earth point.
Power On: Press the red POWER button once. The unit will beep and the LCD will activate.
Zeroing: Point the sensor toward an uncharged area (away from the target). Press the gray ZERO button once or twice until the display reads
Measurement: Move the sensor toward the target surface. Align the two LED guide beams until they merge into a single concentrated circle on the surface.
Hold Function: Press the HOLD button to freeze a reading on the screen for easy recording. Polarity: A negative sign ( −negative
) indicates a negative charge; no sign indicates a positive charge. ⚠️ Maintenance & Safety
Avoid Contaminants: Do not use in areas with water, oil, or conductive solvents to prevent insulation failure.
Cleaning: Gently wipe the sensor area with a cloth lightly moistened with alcohol if it becomes dusty.
Battery Care: Replace the battery when the low-capacity indicator appears. Standard battery life is approximately 30 hours.
No Disassembly: Do not attempt to open or modify the unit, as this can damage sensitive internal sensors. 🛠️ Troubleshooting Common Issues
Inaccurate Readings: Usually caused by a lack of proper grounding or incorrect measuring distance. simco fmx002 manual full
"LO BATT" Display: Unit will not provide reliable data; replace the 9V battery immediately.
Reading Won't Zero: Ensure you are not pointing the sensor at a charged object or your own body while zeroing.
For detailed calibration or professional repair, contact authorized service providers like Micro Precision or refer to official Simco-Ion documentation. FMX-004 - Simco-Ion
The Simco-Ion FMX-002 is a portable electrostatic fieldmeter designed to locate and measure static charges up to ±20plus or minus 20
kV. Below is a comprehensive guide to its operation based on the official manual and technical specifications. 1. Key Specifications Measurement Range: to ±1.49plus or minus 1.49 kV (Low) and ±1.0plus or minus 1.0 to ±20.0plus or minus 20.0 kV (High). Ion Balance Range: to ±200plus or minus 200 V (requires ion balance plate). Accuracy: within standard conditions. Measuring Distance: exactly mm ( inch), indicated by two LED guide lights. Power: 9V manganese battery (approx. 30-hour life). 2. Standard Operation (Static Charge)
Ground the Unit: Connect the supplied grounding lead to the conductive case of the meter to ensure accurate readings.
Power On: Press the POWER button. A single beep confirms operation.
Zeroing: Point the sensor toward a known uncharged or grounded surface and press the ZERO button. The display should read .
Measurement: Aim the sensor at the target object. Move the meter until the two LED guide lights form concentric circles on the surface, ensuring the correct mm distance.
Hold Function: Press the HOLD button to freeze the current reading on the screen. Press it again to return to live measurement. 3. Ion Balance Measurement SIMCO Japan - FMX002 Fieldmeter
Simco FMX-002 is a portable, handheld digital electrostatic fieldmeter designed to locate and measure static charges. Key features and technical specifications derived from the Simco FMX-002 Product Manual Core Measurement Capabilities Dual Range Measurement : 0 to ±1.49 kV. High Range : ±1.0 kV to ±20.0 kV (auto-ranging). Ion Balance Mode
: Measures residual voltage (offset voltage) for ionizers from 0 to ±200 V when the optional metal ion balance plate is attached. Precision Ranging two LED guide lights that form concentric circles to ensure the meter is exactly 25 mm (1 inch) from the test surface for accurate readings. Display & Interface Features Color-Coded Bar Graph for positive polarity voltage. for negative polarity voltage. Digital Readout
: Clear 3-digit numerical display updated 5 times per second. Status Indicators : Retains the current measurement on screen. Battery Capacity : Displays remaining power for the 9V battery. : Appears if the internal sensor is damaged. Operation & Design Push-Button Controls : Simple operation with three main buttons: (reset), and Audible Alarms
: Beeps for power-on, auto-off warning, and over-range alerts. Power Efficiency : Features automatic power-off
after approximately 5 minutes of inactivity to preserve battery life. Safety & Build : The housing is made of conductive resin (ABS)
As you read the FMX-002 manual, you may wonder how it differs from newer models. SIMCO-Ion has since released the FMX-003 and FMX-004. According to their historical documentation:
If you own an FMX-002, the full manual is your Rosetta Stone. If you own a newer unit, search specifically for that model number.
The simco fmx002 manual full is not just a booklet of technical data; it is your roadmap to accurate, reliable electrostatic measurements. From zeroing the device to interpreting over-range warnings, every function is explained in detail.
To summarize your action plan:
Whether you are checking a workstation for harmful static charges, verifying ionizer performance, or troubleshooting a peeling laminate issue, the FMX-002 paired with its full manual is an unbeatable combination.
Do not rely on guesswork. Get the manual, read it cover to cover, and become the ESD expert your team needs. Have a specific issue with your FMX-002
Final Resource Links (hypothetical – check your region):
Have questions about your FMX-002 not covered here? Leave a comment or contact an authorized SIMCO distributor. And remember: when in doubt, consult the simco fmx002 manual full before taking any critical measurement.
Word Count: ~1,850 words. Optimized for the keyword “simco fmx002 manual full” through natural repetition in headings, body text, and actionable sections.
Simco FMX-002 is a portable, battery-operated electrostatic fieldmeter used for measuring static charge potentials up to
. It is designed for precise, "point-and-shoot" measurements in industrial environments to locate and quantify static charges. Core Specifications Measurement Range High Range plus or minus 1.0 Ion Balance (requires attaching a metal balance plate). of reading. Measurement Distance
), precisely guided by two LED "ring lights" that must overlap on the target surface. Response Time : Less than with a display renewal rate of Construction
: Conductive resin (ABS) housing to facilitate proper grounding during use. Display and Interface Digital Display -digit auto-ranging numerical value. Visual Indicators
: Red bars for positive polarity; Blue bars for negative polarity. : Indicates the reading is currently frozen. -stage capacity indicator. : Appears if the internal sensor is damaged. Operational Controls POWER Button
: Press briefly to turn on. For continuous operation (disabling the -minute auto-off), hold the button for more than until three beeps sound. ZERO Button
: Used to calibrate the meter to zero in an uncharged area before starting measurements. HOLD Button
: Freezes the current reading and bar graph, allowing the user to move the meter to a more readable position in tight spaces. MODE/IB Button
: Switches between electrostatic field measurement and Ion Balance measurement mode. Desco Industries Safety and Maintenance
: The device must be grounded using the supplied lead for accurate measurements, especially when testing ion balance. Environment : Operate in environments between relative humidity (non-condensing).
: Continuous beeping indicates an "Over Range" condition; the measurement should be stopped immediately to avoid damaging the sensor. : Ensure no foreign substances touch the internal sensor. Desco Industries For additional support or to purchase the SIMCO FMX-002 Electrostatic Fieldmeter , you can find it at retailers like Rescience Inc or more detail on how to perform the Ion Balance SIMCO Japan - FMX002 Fieldmeter
The Simco FMX-002 is an older, legacy model of the popular electrostatic fieldmeter series. While specific digital manuals for the "002" version are rare, its operation is virtually identical to its successors, the FMX-003 and FMX-004, which are standard handheld tools for measuring static electricity and ion balance.
Below is a guide based on the core functionality shared across this series of Simco-Ion Handheld Fieldmeters. Key Features & Operation
The FMX series uses a non-contact sensor to detect static voltage and displays results in both numerical and bar graph formats.
Measuring Range: Typically measures up to ±20kV (for older models like the 002/003) or ±30kV (for the 004).
Distance Guide: The device is calibrated to be held exactly 1 inch (25mm) from the surface. Look for two red LED guide lights; when the two beams converge into a single concentric circle on the target, you are at the correct distance.
Grounding: For accurate readings, the conductive case must be grounded. This is usually done via the ground lead attached to the side of the unit. Step-by-Step Instructions
Power On: Press the POWER button. A beep should sound, and the LCD will display the battery level. As you read the FMX-002 manual , you
Zeroing: Point the sensor toward an uncharged area (or a grounded metal plate) and press the ZERO button. The display should read "0.00". Taking a Measurement: Move the sensor toward the object you want to test. Stop when the LED guide lights overlap.
The digital readout will show the voltage in kilovolts (kV). A red bar graph indicates positive polarity, while blue indicates negative.
Hold Function: Press the HOLD button to freeze the reading on the screen. This is helpful if you need to measure in a tight space where the screen isn't visible.
Ion Balance Mode (IB): If your unit has an Ion Balance plate (a small metal plate often stored on the back), attach it to the sensor end and press the IB button to measure the balance of your ionizers. Maintenance & Safety
Battery: Uses a standard 9V battery. If the battery indicator is low, replace it by sliding open the back compartment.
Sensor Care: The sensor is extremely sensitive. Never touch it with your fingers or allow it to come into contact with liquids or corrosive gases.
Storage: Always store the device in its protective carrying case to prevent mechanical shock, which can permanently damage the sensor.
If you are looking for a physical copy of the latest documentation to keep on file, the Simco-Ion FMX-004 Manual
provides the most comprehensive and up-to-date safety and technical specifications for this line of products. Operation/Maintenance FMX-003 Electrostatic Fieldmeter
Simco FMX-002 is a compact, portable electrostatic fieldmeter designed for the high-precision measurement of static charges and ion balance
. While often superseded by newer models like the FMX-004, the
remains a staple in industrial environments for identifying static-prone areas and verifying the effectiveness of ionizers Micro Precision Calibration Core Capabilities Static Charge Measurement: Capable of measuring potentials up to $\pm$20 kV (20,000V) at a standardized distance of from the target surface. Ion Balance Testing:
When equipped with an optional metal balance plate, the unit can measure ionizer offset voltage within a range of $\pm$200 V LED Guide System:
Features dual LED guide lights that form a focus point on the target surface, ensuring the user maintains the precise 25 mm measurement distance required for accurate readings. Operational Features
The device utilizes a microprocessor-controlled interface for ease of use in challenging factory environments: One-Touch Zero:
Allows for rapid recalibration to zero before each measurement to eliminate environmental interference. Data Hold Function:
Freezes the current reading on the display, which is particularly useful when taking measurements in hard-to-reach or poorly lit areas. Audible Alarms:
Provides an alert to signify active measurement or when specific thresholds are met. Technical Specifications Measurement Distance 25 mm ($\pm$0.5 mm) guided by LED lights Measurement Range
0 to $\pm$1.49 kV (low range); $\pm$1.0 kV to $\pm$20.0 kV (high range) Ion Balance Range 0 to $\pm$200 V Power Source Typically a 9V dry battery
Conductive resin with a stainless steel grounding snap for safety Safety & Maintenance Grounding:
The fieldmeter must be grounded through the operator or a dedicated ground lead to ensure user safety and measurement accuracy.
Sensors are highly sensitive; do not touch the sensor head and store the device in its protective case when not in use. Most Simco equipment is warranted for from the date of purchase against manufacturing defects.